Fire Ratings - Borrowed Lites/Sidelites
What is the maximum assembly size when fire rated 20 or 45 minute?
10'1" in width and 10'1" in height.
What
is the maximum glass size when using 1/2" glass stop and wire glass?
24" width or 107" height not to exceed 2568 square inches
glass area.
What is the maximum glass size when using
3/4" glass stop and wire glass?
36" width or 54"
height not to exceed 1296 square inches glass area.
What
is the highest fire rating and what are the special requirements?
The frame can be rated up to 60 minutes, but you must use Firelite
glass with GE #2 sealant and install glass stop so that there is a 5/8"
wide glazing recess. (Means: you will have a gap between your glass and
glass stop) You may use 1/2" or 3/4" glass stop and you must use
a setting block.
What is the maximum glass size when
using Firelite Glass?
36" width - but not exceeding 36"
height - but not exceeding 1296 square inches glass area.
Note: If fire rating is not required, Timely has no restrictions on width, heights or total assembly size.